{"id":8264,"date":"2024-03-30T02:28:58","date_gmt":"2024-03-29T21:58:58","guid":{"rendered":"https:\/\/yaghootweb.artinazma.net\/product\/capel-205\/"},"modified":"2025-01-07T14:41:53","modified_gmt":"2025-01-07T11:11:53","slug":"capel-205","status":"publish","type":"product","link":"https:\/\/artinazma.net\/en\/product\/capel-205\/","title":{"rendered":"Capillary electrophoresis system Capel-205"},"content":{"rendered":"<p dir=\"ltr\"><strong>The main advantages of Capel-205 are:<\/strong><\/p>\n<ul class=\"list list-icons\" dir=\"ltr\">\n<li><i class=\"fas fa-check\"><\/i>Great variety of applications may be done thanks to electrophoresis separation technique<\/li>\n<li><i class=\"fas fa-check\"><\/i>One instrument for multiple purposes: detects various types of analytes in almost any kind of aqueous-organic samples<\/li>\n<li><i class=\"fas fa-check\"><\/i>Short analysis time and large autosampler capacity increase lab throughput<\/li>\n<li><i class=\"fas fa-check\"><\/i>No any additional equipment (gas supplier, water bath, etc.) is required: Capel-205 works alone right after installation<\/li>\n<li><i class=\"fas fa-check\"><\/i>Low reagents and sample consumption and standard consumables minimize running costs<\/li>\n<li><i class=\"fas fa-check\"><\/i>No sample evaporation and contamination thanks to sealed vials with automatic opening in the autosampler<\/li>\n<li><i class=\"fas fa-check\"><\/i>21 CFR part 11 compliant software<\/li>\n<li><i class=\"fas fa-check\"><\/i>Streaming potential control technique (optionally) improves repeatability of migration time and accuracy of analysis<\/li>\n<\/ul>\n<div class=\"inner\" dir=\"ltr\"><strong>principle of operation<\/strong><\/div>\n<div class=\"news_child\" dir=\"ltr\">\n<p>Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by an electric field. Separated components are detected and quantified by a highly sensitive optical system based on direct or indirect UV absorbance.<\/p>\n<p>The system uses all main modes of CE (capillary zone electrophoresis (CZE), capillary gel electrophoresis (CGE), capillary isoelectric focusing (CIEF), and others).<\/p>\n<\/div>\n<div class=\"inner\" dir=\"ltr\"><strong>Applications<\/strong><\/div>\n<p dir=\"ltr\"><strong>Environmental analysis<\/strong><\/p>\n<ul dir=\"ltr\">\n<li>Natural, drinking, and waste water (Br<sup>\u2212<\/sup>, Cl<sup>\u2212<\/sup>, F<sup>\u2212<\/sup>, I<sup>\u2212<\/sup>, NO<sub>2<\/sub><sup>\u2212<\/sup>, NO<sub>3<\/sub><sup>\u2212<\/sup>, PO<sub>4<\/sub><sup>3\u2212<\/sup>, SO<sub>4<\/sub><sup>2\u2212<\/sup>, acetate, NH<sub>4<\/sub><sup>+<\/sup>, Ba<sup>2+<\/sup>, Ca<sup>2+<\/sup>, K<sup>+<\/sup>, Mg<sup>2+<\/sup>, Na<sup>+<\/sup>, and other inorganic and organic ions)<\/li>\n<li>Soils, sludge, and sediments (inorganic and organic anions and cations)<\/li>\n<\/ul>\n<p dir=\"ltr\"><strong>Food testing<\/strong><\/p>\n<ul dir=\"ltr\">\n<li>Bottled water (inorganic and organic anions and cations)<\/li>\n<li>All types of non-alcoholic and alcoholic beverages (sugars, sweeteners, preservatives, organic acids, synthetic dyes, antioxidants, inorganic cations and anions), cognacs (aromatic aldehydes)<\/li>\n<li>Foodstuff (sugars, sweeteners, preservatives, flavor enhancers, organic acids, amino acids, inorganic cations and anions), tea &amp; coffee (caffeine, theobromine)<\/li>\n<\/ul>\n<p dir=\"ltr\"><strong>Animal feed &amp; Veterinary<\/strong><\/p>\n<ul dir=\"ltr\">\n<li>Fodder, mixed fodder, and mixed fodder raw materials (amino acids, cations and anions, organic acids, vitamins)<\/li>\n<li>Veterinary drugs (antibiotics, antiprotozoal agents)<\/li>\n<\/ul>\n<p dir=\"ltr\"><strong>Chemical industry<\/strong><\/p>\n<ul dir=\"ltr\">\n<li>Fertilizers (nitrogen (ammonium, nitrate, amide), sulfur, phosphorus, K<sup>+<\/sup>, Na<sup>+<\/sup>, Mg<sup>2+<\/sup>, Ca<sup>2+<\/sup>, Cl<sup>\u2212<\/sup>, F<sup>\u2212<\/sup>)<\/li>\n<li>Technological monitoring<\/li>\n<li>Analysis of raw material<\/li>\n<\/ul>\n<p dir=\"ltr\"><strong>Pharma\/Biopharma<\/strong><\/p>\n<ul dir=\"ltr\">\n<li>Quality control of therapeutic recombinant proteins<\/li>\n<li>Protein separation<\/li>\n<li>Enantiomers separation<\/li>\n<li>Pharmacokinetics studies<\/li>\n<li>and many more<\/li>\n<\/ul>\n<div class=\"inner\" dir=\"ltr\"><strong>equipment and options<\/strong><\/div>\n<ul dir=\"ltr\">\n<li>Capillary electrophoresis system CAPEL-205;<\/li>\n<li>spare capillary cassettes;<\/li>\n<li>Elforun software package;<\/li>\n<li>kits for analyses (by request) *<\/li>\n<\/ul>\n<p dir=\"ltr\">* most of CE-kits of any manufacturers are compatible with Capel-205.<\/p>\n<div class=\"inner\" dir=\"ltr\"><strong>Warranty<\/strong><\/div>\n<p dir=\"ltr\">Lumex Instruments\u2019 CE systems are covered by a full 1-year warranty.<\/p>\n<div class=\"inner\" dir=\"ltr\"><strong>services<\/strong><\/div>\n<p dir=\"ltr\">Installation of CE systems can be carried out at a customer&#8217;s site by our service engineers or by certified distributor service engineers. Personnel training specific to the customer needs can be also provided.<\/p>\n","protected":false},"excerpt":{"rendered":"<p dir=\"ltr\">Capel-205 realizes principle of capillary electrophoresis (CE) \u2013 separation technique, capable to determine multiple components in one run in various types of samples.<\/p>\n<p>Short analysis time and high separation efficiency make CE method a great solution for food industry, environmental applications, pharmaceutical and chemical industries, biochemistry and science.<\/p>\n","protected":false},"featured_media":12518,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false},"product_brand":[],"product_cat":[501],"product_tag":[1005,983,982,920,939,1006],"class_list":["post-8264","product","type-product","status-publish","has-post-thumbnail","product_cat-laboratory-equipment","product_tag-chemical-industries","product_tag-environmental-analysis","product_tag-food-products-analysis","product_tag-laboratory-equipment","product_tag-lumex-en","product_tag-pharmaceutical-industry","pa_brand-lumex-en","pa_standards-astm-d6508-en","pa_standards-astm-d7881-en","pa_standards-iso-171292006-en","first","instock","taxable","shipping-taxable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.6 (Yoast SEO v28.1) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Capillary electrophoresis system Capel-205 | Supplier of laboratory equipment, chemicals<\/title>\n<meta name=\"description\" content=\"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/artinazma.net\/en\/product\/capel-205\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Capillary electrophoresis system Capel-205\" \/>\n<meta property=\"og:description\" content=\"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....\" \/>\n<meta property=\"og:url\" content=\"https:\/\/artinazma.net\/en\/product\/capel-205\/\" \/>\n<meta property=\"og:site_name\" content=\"Supplier of laboratory equipment, chemicals\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-07T11:11:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/artinazma.net\/wp-content\/uploads\/2024\/03\/Capel-205.png\" \/>\n\t<meta property=\"og:image:width\" content=\"449\" \/>\n\t<meta property=\"og:image:height\" content=\"366\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/\",\"url\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/\",\"name\":\"Capillary electrophoresis system Capel-205 | Supplier of laboratory equipment, chemicals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/artinazma.net\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/product-slide1-1-e1764766600649.png\",\"datePublished\":\"2024-03-29T21:58:58+00:00\",\"dateModified\":\"2025-01-07T11:11:53+00:00\",\"description\":\"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/#primaryimage\",\"url\":\"https:\\\/\\\/artinazma.net\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/product-slide1-1-e1764766600649.png\",\"contentUrl\":\"https:\\\/\\\/artinazma.net\\\/wp-content\\\/uploads\\\/2024\\\/03\\\/product-slide1-1-e1764766600649.png\",\"width\":500,\"height\":407,\"caption\":\"\u062f\u0633\u062a\u06af\u0627\u0647 \u0627\u0644\u06a9\u062a\u0631\u0648\u0641\u0648\u0631\u0632 \u0645\u0648\u06cc\u06cc\u0646 CAPEL-205\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/en\\\/product\\\/capel-205\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/artinazma.net\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u0645\u062d\u0635\u0648\u0644\u0627\u062a\",\"item\":\"https:\\\/\\\/artinazma.net\\\/shop\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Capillary electrophoresis system Capel-205\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/#website\",\"url\":\"https:\\\/\\\/artinazma.net\\\/\",\"name\":\"\u062a\u0627\u0645\u06cc\u0646 \u06a9\u0646\u0646\u062f\u0647 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0622\u0632\u0645\u0627\u06cc\u0634\u06af\u0627\u0647\u06cc\u060c \u0645\u0648\u0627\u062f \u0634\u06cc\u0645\u06cc\u0627\u06cc\u06cc\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/artinazma.net\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/#organization\",\"name\":\"\u0622\u0631\u062a\u06cc\u0646 \u0622\u0632\u0645\u0627 \u0645\u0647\u0631\",\"url\":\"https:\\\/\\\/artinazma.net\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/artinazma.net\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/artinazma.net\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Asset-1-2.png\",\"contentUrl\":\"https:\\\/\\\/artinazma.net\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Asset-1-2.png\",\"width\":318,\"height\":116,\"caption\":\"\u0622\u0631\u062a\u06cc\u0646 \u0622\u0632\u0645\u0627 \u0645\u0647\u0631\"},\"image\":{\"@id\":\"https:\\\/\\\/artinazma.net\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.instagram.com\\\/artin.azma\\\/?hl=en\",\"https:\\\/\\\/ir.linkedin.com\\\/company\\\/artinazma\",\"https:\\\/\\\/www.aparat.com\\\/ArtinAzma\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Capillary electrophoresis system Capel-205 | Supplier of laboratory equipment, chemicals","description":"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/artinazma.net\/en\/product\/capel-205\/","og_locale":"en_US","og_type":"article","og_title":"Capillary electrophoresis system Capel-205","og_description":"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....","og_url":"https:\/\/artinazma.net\/en\/product\/capel-205\/","og_site_name":"Supplier of laboratory equipment, chemicals","article_modified_time":"2025-01-07T11:11:53+00:00","og_image":[{"width":449,"height":366,"url":"https:\/\/artinazma.net\/wp-content\/uploads\/2024\/03\/Capel-205.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/","url":"https:\/\/artinazma.net\/en\/product\/capel-205\/","name":"Capillary electrophoresis system Capel-205 | Supplier of laboratory equipment, chemicals","isPartOf":{"@id":"https:\/\/artinazma.net\/#website"},"primaryImageOfPage":{"@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/#primaryimage"},"image":{"@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/#primaryimage"},"thumbnailUrl":"https:\/\/artinazma.net\/wp-content\/uploads\/2024\/03\/product-slide1-1-e1764766600649.png","datePublished":"2024-03-29T21:58:58+00:00","dateModified":"2025-01-07T11:11:53+00:00","description":"Capillary electrophoresis\u00a0is based upon the differential migration of components of aqueous samples within a narrow-fused silica capillary driven by.....","breadcrumb":{"@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/artinazma.net\/en\/product\/capel-205\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/#primaryimage","url":"https:\/\/artinazma.net\/wp-content\/uploads\/2024\/03\/product-slide1-1-e1764766600649.png","contentUrl":"https:\/\/artinazma.net\/wp-content\/uploads\/2024\/03\/product-slide1-1-e1764766600649.png","width":500,"height":407,"caption":"\u062f\u0633\u062a\u06af\u0627\u0647 \u0627\u0644\u06a9\u062a\u0631\u0648\u0641\u0648\u0631\u0632 \u0645\u0648\u06cc\u06cc\u0646 CAPEL-205"},{"@type":"BreadcrumbList","@id":"https:\/\/artinazma.net\/en\/product\/capel-205\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/artinazma.net\/en\/"},{"@type":"ListItem","position":2,"name":"\u0645\u062d\u0635\u0648\u0644\u0627\u062a","item":"https:\/\/artinazma.net\/shop\/"},{"@type":"ListItem","position":3,"name":"Capillary electrophoresis system Capel-205"}]},{"@type":"WebSite","@id":"https:\/\/artinazma.net\/#website","url":"https:\/\/artinazma.net\/","name":"\u062a\u0627\u0645\u06cc\u0646 \u06a9\u0646\u0646\u062f\u0647 \u062a\u062c\u0647\u06cc\u0632\u0627\u062a \u0622\u0632\u0645\u0627\u06cc\u0634\u06af\u0627\u0647\u06cc\u060c \u0645\u0648\u0627\u062f \u0634\u06cc\u0645\u06cc\u0627\u06cc\u06cc","description":"","publisher":{"@id":"https:\/\/artinazma.net\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/artinazma.net\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/artinazma.net\/#organization","name":"\u0622\u0631\u062a\u06cc\u0646 \u0622\u0632\u0645\u0627 \u0645\u0647\u0631","url":"https:\/\/artinazma.net\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/artinazma.net\/#\/schema\/logo\/image\/","url":"https:\/\/artinazma.net\/wp-content\/uploads\/2025\/05\/Asset-1-2.png","contentUrl":"https:\/\/artinazma.net\/wp-content\/uploads\/2025\/05\/Asset-1-2.png","width":318,"height":116,"caption":"\u0622\u0631\u062a\u06cc\u0646 \u0622\u0632\u0645\u0627 \u0645\u0647\u0631"},"image":{"@id":"https:\/\/artinazma.net\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.instagram.com\/artin.azma\/?hl=en","https:\/\/ir.linkedin.com\/company\/artinazma","https:\/\/www.aparat.com\/ArtinAzma"]}]}},"_links":{"self":[{"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/product\/8264","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/comments?post=8264"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/media\/12518"}],"wp:attachment":[{"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/media?parent=8264"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/product_brand?post=8264"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/product_cat?post=8264"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/artinazma.net\/en\/wp-json\/wp\/v2\/product_tag?post=8264"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}