Volumes Available | 2.5/5/10/25 mL, ISO8655-3 |
|---|
|
Application | Maximum number of applications: 5 |
|---|
|
Automatic Reagent Addition(s) | Integrated peristaltic pumps for reagent addition |
|---|
|
Beaker Volumes Accepted | System specific beakers: Polypropylene, 50 mL & 150 mL with clips
Generic beakers supported: Up to 250 mL low form glass |
|---|
|
Burette | 1 |
|---|
|
Burette Motor Resolution | 20,000 steps with electronic µstepping technology (128 µsteps/step) |
|---|
|
Calibration | Titrant & electrode (up to 5 buffers in Auto Mode, fixed & user defined) |
|---|
|
Calibration Curves Display | Direct & derivative titration curves, electrode calibration curve |
|---|
|
Calibration Intervals/Alerts/Reminder | Yes, user defined period |
|---|
|
Certifications | Safety IEC/EN 61010-1; EMC IEC/EN 61326-1 |
|---|
|
Data Export | On USB Key, CSV type, Excel compatible. |
|---|
|
Data Memory | Last 100 samples, QC & blank analyses, last 10 calibrations |
|---|
|
Data Storage | Date, Time, Operator IDs, Sample IDs |
|---|
|
Display Type | 5,7"; Graphic colour; VGA |
|---|
|
Electrode | IntelliCAL ("Plug & Play" digital), analog, photocolorimetric; 2 inputs available |
|---|
|
Embedded Procedures | Tubing bubble purging, reagent priming, burette and pump replacement |
|---|
|
Installation Category | Category II |
|---|
|
Maintenance Scheduler | Yes, user defined |
|---|
|
Material Enclosures | PP Latene, Silicone, Hardered Glass, POM, Stainless steel. Splashproof design |
|---|
|
Measurement Method | Potentiometric (zero & imposed current), amperometric, colorimetric |
|---|
|
Measurement Modes | End Point, Inflection Point – Sample, Blank, Sample with Blank, QC Sample, QC Sample with Blank |
|---|
|
Operating Conditions | 15 – 35 °C (59 – 95 °F), 20 – 80 % RH, non-condensing |
|---|
|
Operating Humidity | 20 – 80 % (non-condensing) |
|---|
|
Operating Interface | Soft keypad (silicone) |
|---|
|
Outputs | Electrode ports (x2), USB (x2), Serial (x1), Ethernet (x1) |
|---|
|
Parameter | mV/pH, Conductivity, Temperature (°C or °F) |
|---|
|
Password Protection | Yes, user defined |
|---|
|
Pollution Degree | 2 |
|---|
|
Power Requirements (Hz) | 50/60 Hz |
|---|
|
Power Requirements (Voltage) | 100/240 VAC |
|---|
|
Pump flow rate | 100 mL/min |
|---|
|
Pumps | 2 |
|---|
|
Required Application Package/s | AP0007.AT1122 Free & Total Chlorine, Chlorine Dioxide, Chlorite, & Sulfite (Autocat)
AP0012.AT1122 Free & Total SO₂ in wine |
|---|
|
Resolution | mV/pH: ±0.1 mV / ±0.001 pH, Conductivity: ±0.5 % of reading, Temperature: ±0.3 °C |
|---|
|
Sample Stand | Integrated, magnetic stirring, beakers up to 250 mL |
|---|
|
Storage Conditions | -5 to 40 °C (23 to 104°F) |
|---|
|
Supported Peripherals | Printer, PC software, balance, sample changer, keyboard, mouse, barcode reader, sampling pump, propeller stirrer |
|---|
|
Titration Modes | Sample, blank, sample with blank, QC sample, QC sample with blank |
|---|
|
Titration Types | Potentiometric (zero & imposed current), amperometric, colorimetric |
|---|
|
Warranty | 12 months |
|---|
|
Weight | 4 kg |
|---|
|
What's included? | Hach AT1122 Instrument, Tube Holder, Sensor Storage Tubes, Power Supply, Power Cord, Manual Sold Separately: Don't forget to order your Application Pack and Reagents and consider purchasing a Sample Changer! |
|---|
|
brand | HACH |
|---|