Paraffin and ceresin penetration tester LinteL PN-10PC
Paraffin and ceresin penetration test
- LinteL PN-10 allows you to set the following test conditions:
– penetration time in increments of 1s;
– delay time before penetration is performed in steps of 1s. - The device determines the penetration value with an error of ±0.1 mm.
- The device is equipped with a built-in illuminator and a magnifying glass, which help determine the moment the needle touches the bitumen surface.
- The device provides storage of up to 9 determination results with calculation of their average value.
- Integration with the LinteL Link data collection system allows you to collect and transfer laboratory test results from the device to a personal computer via wireless communication. Integration with the laboratory information system Lintel LIS provides comprehensive automation of laboratory activities.
- The device is equipped with a liquid bath with a heat exchanger for connecting a thermocryostat (for example, Lintel TKS-20).
- Control of table movement in three modes: slow table lift, fast table lift, fast table return.
- Display on the display in standby mode: the number of the last test performed; a given number of tests; table lifting speed; specified penetration time; specified delay time.
- Display on the display during the test: the number of the last test performed; a given number of tests; penetration time (countdown); current penetration value.
- The four-line OLED display provides an intuitive user interface with all the information you need while testing and viewing results.
- Full self-diagnosis system with indication of the causes of malfunctions on the display.
- Stopping the test process at the end of the analysis with an audible alarm.
Safety:
Sound accompaniment |
Sound signal when the test is completed or a malfunction is detected |
Diagnostics and setup |
Built-in self-diagnosis and configuration algorithms, notifying users about the causes of malfunctions
|
Equipment:
Apparatus for determining the penetration of petroleum products LinteL® PN-10 |
1 PC. |
|
Calibration rod, 63 mm |
1 PC. |
|
Calibration rod, 40mm |
1 PC. |
|
Calibration rod, 50mm |
1 PC. |
|
Verification rod |
1 PC. |
|
Plate |
1 PC. |
|
Level, L< 400 mm |
1 PC. |
|
Manual |
1 PC. |
|
Passport |
1 PC. |
|
Certificate for calibration rods |
1 PC. |
|
Certification program and methodology |
1 PC. |
|
GR complete set (EN 13880-3, ASTM D 5329) |
||
Cup for sealants |
2 pcs. |
|
Cylindrical stand |
1 PC. |
|
Ball tip |
2 pcs. |
Penetration range* |
from 0 to 630 penetration units |
---|---|
Displacement meter error |
±0.1mm |
Penetration time |
from 1 to 3599 s |
Delay time before penetration |
from 0 to 3599 s |
Table speed |
from 0.02 to 5.0 mm/s |
Power consumption |
no more than 50 W |
Penetrometer dimensions |
245x505x280mm (width x height x depth) |
Penetrometer weight |
no more than 12 kg |
Ambient temperature |
from 10 to 35 °C |
Relative humidity at +25°C |
no more than 80% |
Mains voltage |
from 198 to 242 V |
Power frequency |
49 to 51 Hz |
Life time |
6 years, no more than 15,000 hours |
Warranty period |
1 year, no more than 2,500 hours |
Standards | |
brand |