Automatic open cup tester (with gas ignition) Cleveland method LinteL®ATVO-21

measure the flash point temperature and flash point of all petroleum and hydrocarbon products and cuts

SKU: lintel-atvo-21 Category:

This test method is used to measure the flash point temperature and flash point of all petroleum and hydrocarbon products and cuts that have a flash point of at least 79 and a maximum of 380 degrees Celsius.

The Clevland open-cup method is used to measure the open flash point of all petroleum products with an open flash point in the temperature range of at least 79 and at a maximum of 400 ° C, except for furnace oil.

Safety

Beeping at the end of the test and failure detection

Audio signals

Built-in algorithms for self-diagnostics, user notification about causes of malfunctions

Diagnostic and setting

Differential automatic circuit breaker, preventing electric shock for the user and the tester damage due to short circuit, complete tester disconnection from power supply under all modes, except test one.

Electrical safety

Measuring range

from +79 to +400 °С

Discreteness of the flash-point result determination

1 °C

Type of the product vapor ignition

gas ignition

Product heating rate

5–6 °C/min

Product heating rate up to temperature by 56 °C below expected flash point

14–17 °C/min

ACCURACY PARAMETERS

5 °C max

Reading repeatability limit of the tester

5 °C max

Reading reproducibility limit

16 °С max

Barometric pressure

±1 mm Hg

Power consumption under standby mode

150 max

Power consumption under test mode

1,000 W max

Overall dimensions

330 х 420 х 310 mm (depth x width x height)

Weight

21 kg max

Ambient air temperature

from +15 to +35 °С

Relative air humidity

75 % max

Voltage

from 187 to 242 V

Frequency

from 49 to 51 Hz

Probability of failure-free operation within 1,000 h, min

0.96

Service

6 year, but 15,000 hours max

Guaranteed service life

1 year, but 2,500 hours max

Standards

brand

ASTM D 92