AT1000 Potentiometric Titrator Model AT1122

Simplify complex titration with the Titralab AT1000 from Hach. Straight from the box the AT1000 eliminates operator interpretation and manual processes you have come to expect with existing manual titration

SKU: AT1000 Potentiometric Titrator Model AT1122 Category: Tags: ,

Automatic titration without all the costs and complications

Simplify complex titration with the Titralab AT1000 from Hach. Straight from the box the AT1000 eliminates operator interpretation and manual processes you have come to expect with existing manual titration. The automatic system gives you more reliable results without complicated analysis. To make setup and titration simple, the AT1000 utilizes application specific kits to make it quick and easy for anyone to set up and operate a test.

The AT1122 instrument can be used with the following Hach Application Packs:
– Free & Total Chlorine, Chlorine Dioxide, Chlorite, Sulfite (AP0007.AT1122)
This application pack is designed to replace the Autocat 9000 Chlorine Amperometric Titrator
– Free & Total SO₂ in wine (AP0012.AT1122)
– The AT1122 can also run any applications listed for the AT1102 and AT1112

Volumes Available

2.5/5/10/25 mL, ISO8655-3

Application

Maximum number of applications: 5

Automatic Reagent Addition(s)

Integrated peristaltic pumps for reagent addition

Beaker Volumes Accepted

System specific beakers: Polypropylene, 50 mL & 150 mL with clips
Generic beakers supported: Up to 250 mL low form glass

Burette

1

Burette Motor Resolution

20,000 steps with electronic µstepping technology (128 µsteps/step)

Calibration

Titrant & electrode (up to 5 buffers in Auto Mode, fixed & user defined)

Calibration Curves Display

Direct & derivative titration curves, electrode calibration curve

Calibration Intervals/Alerts/Reminder

Yes, user defined period

Certifications

Safety IEC/EN 61010-1; EMC IEC/EN 61326-1

Data Export

On USB Key, CSV type, Excel compatible.

Data Memory

Last 100 samples, QC & blank analyses, last 10 calibrations

Data Storage

Date, Time, Operator IDs, Sample IDs

Display Type

5,7"; Graphic colour; VGA

Electrode

IntelliCAL ("Plug & Play" digital), analog, photocolorimetric; 2 inputs available

Embedded Procedures

Tubing bubble purging, reagent priming, burette and pump replacement

Installation Category

Category II

Maintenance Scheduler

Yes, user defined

Material Enclosures

PP Latene, Silicone, Hardered Glass, POM, Stainless steel. Splashproof design

Measurement Method

Potentiometric (zero & imposed current), amperometric, colorimetric

Measurement Modes

End Point, Inflection Point – Sample, Blank, Sample with Blank, QC Sample, QC Sample with Blank

Operating Conditions

15 – 35 °C (59 – 95 °F), 20 – 80 % RH, non-condensing

Operating Humidity

20 – 80 % (non-condensing)

Operating Interface

Soft keypad (silicone)

Outputs

Electrode ports (x2), USB (x2), Serial (x1), Ethernet (x1)

Parameter

mV/pH, Conductivity, Temperature (°C or °F)

Password Protection

Yes, user defined

Pollution Degree

2

Power Requirements (Hz)

50/60 Hz

Power Requirements (Voltage)

100/240 VAC

Pump flow rate

100 mL/min

Pumps

2

Required Application Package/s

AP0007.AT1122 Free & Total Chlorine, Chlorine Dioxide, Chlorite, & Sulfite (Autocat)
AP0012.AT1122 Free & Total SO₂ in wine

Resolution

mV/pH: ±0.1 mV / ±0.001 pH, Conductivity: ±0.5 % of reading, Temperature: ±0.3 °C

Sample Stand

Integrated, magnetic stirring, beakers up to 250 mL

Storage Conditions

-5 to 40 °C (23 to 104°F)

Supported Peripherals

Printer, PC software, balance, sample changer, keyboard, mouse, barcode reader, sampling pump, propeller stirrer

Titration Modes

Sample, blank, sample with blank, QC sample, QC sample with blank

Titration Types

Potentiometric (zero & imposed current), amperometric, colorimetric

Warranty

12 months

Weight

4 kg

What's included?

Hach AT1122 Instrument, Tube Holder, Sensor Storage Tubes, Power Supply, Power Cord, Manual

Sold Separately: Don't forget to order your Application Pack and Reagents and consider purchasing a Sample Changer!

brand

هیچ ویدیویی برای این محصول موجود نیست.

Accurate and Reliable Titration Results

• Eliminates errors in manual processes and operator interpretation
• Pre-programmed titration methods automatically detect endpoints and perform calculations
• High resolution electronic burette with 20,000 steps
• Automatic sample preparation using embedded peristaltic pumps
• High performance probes for reliable measurements

Easy to Use for all Operators

• Press one button to get the correct result
• Operators of all skill levels can get accurate measurements
• No need for custom programming with Hach’s unique application specific routines
• Simple user interface with large color display that shows the titration curve as it is measuring
• USB ports to quickly and easily capture data to a PC and attach optional keyboard/mouse or printer

Low Cost of Ownership

• Reduces the amount of reagent used for every titration cutting cost of ownership month after month
• Increases lab throughput by allowing operator to prepare next sample while titrator performs measurement
• Adding an AS1000 sample changer allows the operator to load multiple samples and come back for results later

Improves Lab Safety

• Minimizes direct contact with reagents
• No need for potentially dangerous colored indicators
• Instrument can be easy and safely moved thanks to the compact design

Low Maintenance

• Reliable design significantly reduces downtime
• Extended periods between maintenance routines
• Maintenance is simple and easy to perform