Atomic Absorption Spectrometer MGA-1000
MGA-1000 is a graphite furnace atomic absorption spectrometer based on the patented Zeeman High Frequency Polarization Modulation (ZHFPM) technique.
MGA-1000 is intended for determination of a wide range of elements in various types of samples (water, soil, foodstuffs, fodders, pharmaceuticals, etc.).
The instrument performs high selectivity and sensitivity of analysis.
Graphite Furnace Atomic Absorption Spectrometry (GFAAS) provides optimal combination of high selectivity and sensitivity with low running cost. The unique ZHFPM background correction technique ensures effective compensation of intense and rapidly changing spectral interferences and brings routine analysis of complex samples to new heights.
ZHFPM background correction is effective in all spectral range
MGA-1000 optical scheme
- Simultaneous measurement of total and background absorptions
- Simple direct analysis of samples with high salinity and organic content: blood, body fluids, sea water, brines, food and soil digests, etc.
- Smart 47-position autosampler supports standard centrifuge-type tubes
- Effective cooling system included
- Stabilized temperature platform furnace (STPF) concept implemented
- No flammable gases nor air compressor needed, argon only is used for operation
- Standard graphite tubes (28 mm) of both Massman and L’vov types are available, tube lifetime is prolonged
- Quasi-double beam optics eliminate drifts and enable direct work with no warm-up needed
- Low detection limits and direct determination of As, Se, and other elements at levels from 1 ppb without hydride generation technique or preconcentration
- Analysis of Na, K, Mg, and Ca from sub-ppb to hundreds of ppm levels
- 6-lamps turret supports both hollow cathode lamps and electrodeless discharge lamps (EDL)
- Compact size of instrument and noiseless operation: fits in regular lab, no requirements for separate room
- Cold Vapor/Hydride Generation accessory for Hg analysis
MGA-1000 spectrometer is an excellent solution for reliable and accurate trace elements and macro elements analysis in various industries:
- Environmental monitoring
- Water treatment
- Food and beverages
- Agriculture
- Pharmaceutics and life science
- Medicine and biochemistry
- Forensics and clinical research
- Petrochemistry and refineries
- Process control and material analysis
- Science and research
User-friendly Eltherm software for instrument operation, results processing and storage complies with 21 CFR part 11 requirements and provides automatic self-diagnostics and safety control.
- Atomic Absorption Spectrometer MGA-1000;
- Autosampler;
- Eltherm software package;
- Spectral lamps (for elements of interest);
- Graphite furnace tubes;
- Hydride system RGP-915 (optional for trace analysis of Hg);
- Kits for analyses (by request).
MGA-1000 spectrometer is covered by a full 1-year warranty.
Installation and commissioning can be carried out at a customer site by our service engineers or by certified distributor service engineers.
Spectral range |
185 – 900 nm |
---|---|
Furnace heating rate |
up to 4500 K/sec |
Non-selective absorbance correction |
Zeeman background correction with high-frequency modulation of light polarization |
Argon flow rate (high purity argon) |
< 2.0 l/min |
Maximal temperature of the furnace atomizer |
3000 °C |
Spectral lamps |
– Hollow Cathode Lamps |
Lamp turret |
Revolver turret for 6 lamps |
Atomizer cooling |
Closed-loop water cooling system |
Typical tube lifetime |
800 analysis cycles |
Autosampler capacity |
47 samples |
Power supply |
Three-phase 220/380VAC, 50/60 Hz |
Size |
800 × 475 × 310 mm |
Weight |
50 kg |
brand |
هیچ ویدیویی برای این محصول موجود نیست.
Element | Wavelength, nm | Absolute Detection Limit, pg | Relative Detection Limit, µg/l |
---|---|---|---|
Ag | 328.1 | 0.2 | 0.005 |
Al | 309.3 | 1.5 | 0.038 |
As | 194.0 | 4 | 0.1 |
Au | 242.8 | 4 | 0.1 |
Ba | 553.6 | 12 | 0.3 |
Be | 234.9 | 0.4 | 0.01 |
Bi | 306.8 | 16 | 0.4 |
Cd | 228.8 | 0.01 | 0.00025 |
Co | 240.7 | 6 | 0.15 |
Cr | 357.9 | 0.4 | 0.01 |
Cu | 324.7 | 1 | 0.025 |
Fe | 248.3 | 2 | 0.05 |
Hg | 253.7 | 10 (0.002*) | 0.25 (0.002*) |
Li | 670.8 | 2 | 0.05 |
Mn | 279.5 | 1 | 0.025 |
Mo | 313.3 | 4 | 0.1 |
Ni | 232.0 | 4 | 0.1 |
Pb | 283.3 | 2 | 0.05 |
Pd | 244.8 | 4 | 0.1 |
Pt | 265.9 | 30 | 0.75 |
Sb | 231.2 | 4 | 0.1 |
Se | 196.1 | 4 | 0.1 |
Sn | 286.3 | 4 | 0.1 |
Sr | 460.7 | 1.1 | 0.028 |
Ti | 364.3 | 20 | 0.5 |
Tl | 276.8 | 2 | 0.05 |
V | 318.4 | 4 | 0.1 |
Zn | 213.9 | 0.01 | 0.00025 |
Zn | 307.6 | 50 | 1.25 |