Distillation in Petroleum Products ARNS-21
Quantitatively determine the boiling range of petroleum products
- Preset test programs. Each test program contains a standard, group, test parameters and report form. Thus, when selecting a program, all necessary parameters and test conditions are set and maintained automatically.
- The report form editor allows you to set the required points, both for temperature and distillation, and determine the need to make adjustments for atmospheric pressure and losses. The required report parameters can be changed when viewing the result.
- Automatic fire extinguishing system.
- Integration with the Lintel Link data collection system allows for collection and transmission of laboratory test results from the device to a personal computer via wireless communication. Integration with the Lintel LIS laboratory information system provides comprehensive automation of laboratory activities.
- Test logging provides storage of up to 200 test results and distillation graphs, as well as additional information on test compliance.
- Measurement of vapor temperature, bath temperature and receiver temperature.
- Measuring volume in a graduated cylinder.
- Residual measurement, both in manual and automatic mode.
- Automatic correction for barometric pressure in the range from 630 to 810 mmHg.
- Sound signaling of the start of boiling and the end of distillation.
- Automatic cooling of the heater at the end of distillation, with cooling of the heater to a temperature 5ºС above room temperature.
- Convenient, intuitive menu for selecting a test program, navigating through the test log, diagnostics and device settings.
- Full self-diagnostic system with indication of the causes of malfunctions on the display.
- Possibility of updating the device software remotely.
Discharge temperature |
Oil and oil products with a boiling point of +18 to +400 ° C |
---|---|
Oil product groups |
dark oil products, oil, paraffin oil, paraffins according to GOST 2177 (ISO 3405) Method B;1, 2, 3, 4 according to GOST 2177 (ISO 3405) Method A; 1, 2, 3, 4 according to GOST R EN ISO 3405; 1, 2, 3, 4 according to ASTM D 86. |
The volume of the distilled product, ml |
± 0.3 |
Product vapor temperature |
from 0 to 300: ± 1.0, from 300 to 400: ± 1.5 |
Barometric pressure |
± 1 |
Cooling bath temperature |
from 0 to 60: ± 0.5 |
Receiver temperature |
from 13 to 60: ± 0.5 |
Speed of distillation, ml / min |
from 0 to 9: ± 0.5 |
Power Consumption |
not more than 1500 V · A |
Dimensions |
750 x 585 x 515 mm (height x width x depth) |
Weight |
not more than 50 kg (without taking into account the coolant in the bath) |
Ambient temperature |
+15 to +35 ° C |
Relative humidity |
not more than 75% |
Voltage |
from 187 to 242 V |
Frequency |
from 49 to 51 Hz |
Warranty period of operation |
1 year, not more than 2 500 hours (does not apply to glassware) |
Life time |
6 years, no more than 15 000 hours |
Warranty period |
1 year, not more than 2 500 hours |